Ir al contenido

Documat


Uncertainty analysis of a test-rig for centrifugal compressors

  • Valencia, Esteban [1] ; Granja, Victoria [2] ; Palacios, Jose [2] ; Poveda, Ricardo [2] ; Cando, Edgar [3] ; Hidalgo, Victor [3]
    1. [1] Cranfield University

      Cranfield University

      Cranfield, Reino Unido

    2. [2] Escuela Politécnica Nacional

      Escuela Politécnica Nacional

      Quito, Ecuador

    3. [3] Tsinghua University

      Tsinghua University

      China

  • Localización: Revista Politécnica, ISSN-e 2477-8990, Vol. 35, Nº. 3, 2015 (Ejemplar dedicado a: Revista Politécnica), págs. 19-19
  • Idioma: inglés
  • Enlaces
  • Resumen
    • Resumen: El presente trabajo establece el procedimiento experimental llevado a cabo para obtener las curvas características de un compresor, y busca describir el método de propagación de incertidumbres en los resultados finales de un banco de pruebas para compresores centrífugos y de esta forma calibrar la apreciación de la instrumentación y mejorar así su precisión. Se ha desarrollado un método numérico para considerar todas las incertidumbres, errores y factores de calibración de los diferentes instrumentos de medición y procesamiento de información. Se realiza el análisis de los datos obtenidos experimentalmente y se muestra una comparación entre la gráfica experimental del compresor y la gráfica dada por el fabricante. Adicionalmente, se realiza un análisis de la incertidumbre de los datos experimentales para encontrar los parámetros que interfieren en mayor grado sobre las curvas características del compresor. Abstract: This work stablishes the experimental procedure aimed to obtain a compressor performance map, and the description of the uncertainty propagation method in the final results of a test-rig for centrifugal compressors to improve the accuracy and therefore the precision of the experimental set-up. A mathematical method has been developed to implement all the uncertainties, errors and calibration factors of the different measuring and processing devices. The analysis of the experimental data is performed. A comparison between the experimental compressor map and the original equipment map (OEM) is shown. Additionally, an uncertainty analysis of the experimental data is performed to find the parameters that affect largely the compressor map.

  • Referencias bibliográficas
    • "Catalog of Pressure Sensor AE-SML-10", Ae sensors, 2005.
    • "Data Sheet for Flowmeter Steel Mass Model 640S", Sierra Instruments, 2009.
    • "Ni cDAQ 9172 User’s Manual", National Instruments, NI Press, Austin, TX, 2010.
    • "Ni9201, Ni9203, Ni9265, Ni 9211 User’s Manuals", National Instruments, NI Press, Austin, TX, 2010.
    • "Product Data Industrial Mineral Insulated Thermocouples, fitted miniature plug, Type K", Lab. Facility temperature and process technology.
    • "Revised Thermocouple Reference Tables Type K", N.I.S.T, Monograph 175, Revised to ITS-90.
    • "Test Uncertainty ASME PTC 19.1", ASME, 2005.
    • "User’s guide for Pico Turn-2G", ACAM Mess Electronic.
    • H.W.Coleman, W.G.Steele, "Experimentation and uncertainty analysis for engineers", 3rd. ed., Ed. New York: John Wiley & Sons Press.,2009
    • J. Buijtenen, W. Visser, "Thermodynamics and Gas Turbines, AE3-235", Third edition, TU Delft, 2007.
    • Thermocouple Accuracy Table by Type and Temperature, Internet: http://digital.ni.com/public.nsf/allkb/776AB03E065228408625727B00034E20?OpenDocument,...
    • W.Visser, S.Shakariyants, "Development of a 3 kW Microturbine for CHP Applications", Journal of Engineering for Gas Turbines and Power,...