Comparación entre la ecografía pulmonar transtorácica y el método clínico para confirmar la posición del tubo de doble luz izquierdo en anestesia torácica: Estudio piloto

  • N. Álvarez Díaz ; I. Amador García ; M. Fuentes-Hernández ; Roberto Dorta Guerra [1]
    1. [1] Universidad de La Laguna

      Universidad de La Laguna

      San Cristóbal de La Laguna, España

  • Localización: Revista española de anestesiología y reanimación, ISSN 0034-9356, Vol. 62, Nº. 6, 2015, págs. 305-312
  • Idioma: español
  • DOI: 10.1016/j.redar.2014.06.005
  • Títulos paralelos:
    • Comparison between transthoracic lung ultrasound and a clinical method in confirming the position of double-lumen tube in thoracic anaesthesia: A pilot study
  • Texto completo no disponible (Saber más ...)
  • Resumen
    • español

      Objetivo Comparar la capacidad de la ecografía pulmonar y del método clínico para confirmar una intubación selectiva mediante un tubo de doble luz izquierdo en cirugía torácica electiva.

      Material y métodos Estudio observacional, ciego y prospectivo, realizado en el quirófano de cirugía torácica de un hospital universitario en el que a un grupo de 105 pacientes consecutivos, de un total de 130, tras la intubación traqueal con un tubo de doble luz izquierdo se les confirmó la posición del tubo clínicamente y por ecografía para, finalmente, aplicarles la confirmación fibrobroncoscópica considerada estándar de referencia. Bajo ventilación manual, tras el pinzamiento secuencial de los lúmenes traqueal y bronquial, la confirmación clínica se realizaba mediante auscultación, capnografía, visualización de los movimientos del tórax y percepción de la compliancia pulmonar en la bolsa reservorio. La confirmación ecográfica se practicaba mediante la visualización del deslizamiento pulmonar, los movimientos diafragmáticos y la aparición del signo pulso pulmón.

      Resultados La sensibilidad del método clínico fue del 84,5%, la especificidad fue del 41,1%, el cociente de probabilidad positivo fue 1,44, y el cociente de probabilidad negativo fue 0,38. La sensibilidad del método ecográfico fuel 98,6%, la especificidad fue del 52,9%, el cociente de probabilidad positivo fue 2,10, y el cociente de probabilidad negativo fue 0,03. La comparación del contraste de sensibilidades y especificidades de ambos métodos se realizó mediante el test de McNemar. Había una diferencia significativa entre la sensibilidad del método ecográfico y el método clínico (p = 0,002), no encontrándose diferencia significativa entre las especificidades de ambos test (p = 0,34). El nivel de significación estadístico considerado fue p < 0,01.

      Conclusión El método ecográfico fue superior al clínico para comprobar la correcta colocación del tubo de doble luz izquierdo, pero para diagnosticar la malposición del tubo no se puede asegurar que haya diferencias entre ambos métodos.

    • English

      Objective To compare the ability of lung ultrasound and a clinical method in the confirmation of a selective bronchial intubation by left double-lumen tube in elective thoracic surgery.

      Material and methods A prospective and blind, observational study was conducted in the setting of a university hospital operating room assigned for thoracic surgery. A single group of 105 consecutive patients from a total of 130, were included. After blind intubation, the position of the tube was confirmed by clinical and ultrasound assessment. Finally, the fiberoptic bronchoscopy confirmation as a reference standard was used to confirm the position of the tube. Under manual ventilation, by sequentially clamping the tracheal and bronchial limbs of the tube, clinical confirmation was made by auscultation, capnography, visualizing the chest wall expansion, and perceiving the lung compliance in the reservoir bag. Ultrasound confirmation was obtained by visualizing lung sliding, diaphragmatic movements, and the appearance of lung pulse sign.

      Results The sensitivity of the clinical method was 84.5%, with a specificity of 41.1%. The positive and negative likelihood ratio was 1.44 and 0.38, respectively. The sensitivity of the ultrasound method was 98.6%, specificity was 52.9%, with a positive likelihood ratio of 2.10 and a negative likelihood ratio of 0.03. Comparisons between the diagnostic performance of the 2 methods were calculated with McNemar's test. There was a significant difference in sensitivity between the ultrasound method and the clinical method (P = .002). Nevertheless, there was no statistically significant difference in specificity between both methods (P = .34). A p value < .01 was considered statistically significant.

      Conclusion Lung ultrasound was superior to the clinical method in confirming the adequate position of the left double-lumen tube. On the other hand, in confirming the misplacement of the tube, differences between both methods could not be ensured.

  • Referencias bibliográficas
    • 1 S. Saito, S. Dohi, H. Naito Alteration of double-lumen endobronchial tube position by flexion and extension of the neck Anesthesiology,...
    • 2 R.H. Riley, I.L. Marples Recolocation of a double-lumen tube during patient positioning Anesth Analg, 75 (1992), p. 1071 ...
    • 3 J.B. Brodsky, J.M. Lemmens Left double-lumen tubes: Clinical experience with 1,170 patients J Cardiothorac Vasc Anesth, 17 (2003),...
    • 4 J.H. Campos Update on tracheobronchial anatomy and flexible fiberoptic bronchoscope in thoracic anesthesia Curr Opin Anaesthesiol,...
    • 5 M.S. Kristensen Ultrasonography in the management of the airway Acta Anaesthesiol Scand, 55 (2011), pp. 1155-1173 CrossRefView...
    • 6 A. Sustić Role of ultrasound in the airway management of critically ill patients Crit Care Med, 35 (5 Suppl) (2007), pp. S173-S177 ...
    • 7 A. Sustić, A. Protić, T. Cicvarić, Z. Zupan The addition of a brief ultrasound examination to clinical assessment increases the...
    • 8 N.B. Islam, P.D. Levy Emergency bedside ultrasound to detect pneumothorax Acad Emerg Med, 10 (2003), pp. 819-820 View Record...
    • 9 P. Slinger A view of and through double-lumen tubes J Cardiothorac Vasc Anesth, 17 (2003), pp. 287-288 Article Download...
    • 10 M. Yasumoto, K. Higa, K. Nitahara, S. Shono, T. Hamada Optimal depth of insertion of left-sided double-lumen endobronchial tubes...
    • 11 J.B. Brodsky Lung separation and the difficult airway Br J Anaesth, 103 (Suppl 1) (2009), pp. i66-i75 Article Download...
    • 12 K. Takita, Y. Morimoto, O. Kemmotsu The height-based formula for prediction of left-sided double-lumen tracheal tube depth ...
    • 13 T. Sakuragi, K. Kumano, M. Yasumoto, K. Dan Rupture of the main-stem bronchus by the tracheal portion of a double-lumen endobronchial...
    • 14 M.S. Mikhail, D. Thangathurai Anesthesia for thoracic surgery G.E. Morgan Jr., M.S. Mikhail (Eds.), Clinical Anesthesiology...
    • 15 G.B. Smith, N.P. Hirsch, J. Ehrenwerth Placement of double-lumen endobronchial tubes. Correlation between clinical impressions...
    • 16 U. Klein, W. Karzai, F. Bloos, M. Wohlfarth, R. Gottschall, H. Fritz, et al. Role of fiberoptic bronchoscopy in conjunction with...
    • 17 S. Inoue, N. Nishimine, K. Kitaguchi, H. Furuya, S. Taniguchi Double lumen tube location predicts tube malposition and hipoxaemia...
    • 18 M. De Bellis, R. Accardo, M. di Maio, C. La Manna, G.B. Rossi, M.C. Pace, et al. Is flexible bronchoscopy necesary to confirm the...
    • 19 G.W. Fischer, E. Cohen An update on anesthesia for thoracoscopic surgery Curr Opin Anaesthesiol, 23 (2010), pp. 7-11 View...
    • 20 P. Apostolou, A. Tsantsaridou, I. Papasotiriou, M. Toloudi, M. Chatzioannou, G. Giamouzis Bacterial and fungal microflora in surgically...
    • 21 M. Schweigert, A. Dubecz, M. Beron, D. Ofner, H.J. Stein Pulmonary infections imitating lung cancer: Clinical presentation and...
    • 22 M. Blaivas, J.W. Tsung Point-of-care sonographic detection of left endobronchial main stem intubation and obstruction versus endotracheal...
    • 23 D.A. Lichtenstein Pneumothorax Whole body ultrasonography in the critically ill, Springer-Verlag, Berlin, Heidelberg (2010),...
    • 24 D.A. Lichtenstein, N. Lascols, S. Prin, G. Mezière The “lung pulse”: An early ultrasound sign of complete atelectasis Intensive...

Fundación Dialnet

Mi Documat

Opciones de artículo

Opciones de compartir

Opciones de entorno